Manual Philips IntelliVue Telemetry System Instructions for Use (order number M4841-91001). Note—Standard and EASI M2601A Transmitters can be used with the Philips Telemetry System and can operate simultaneously with M2601B Transmitters. “What’s New” on page 1-2 summarizes the differences between the M2601B and M2601A transmitters. Monitoring System, as well as the Philips Neonatal CMS Patient Monitoring System will be referred to throughout this guide as the CMS. Target Audience This reference guide is intended for hospital Biomedical Engineers and Technicians, Philips Customer Engineers, Response Center Engineers, and Installation Planning Specialists who have. The Philips IntelliVue Telemetry System uses a cellular architecture to provide two-way communications between patient-worn transceivers and the IntelliVue Information Center. The Philips IntelliVue Telemetry System consists of two types of transceivers (portable patient-worn devices) - one with integrated ECG.
Patient Monitors. Efficia CM Patient Monitors: CM10 -883301, CM12 – 883303, CM100-883300, CM120-883302, CM150-883304. Telemetry: Philips Telemetry System. Philips Telemetry System Quick Reference Service Guide Contents. If a 4-wire leadset has been installed, monitoring is not possible. Replace with a 3- or 5 wire leadset. If the transmitter is a standard ECG transmitter. Must be set to Manual using the Telemetry Service Tool or Wave Viewer. After making a manual SpO.
- Philips M2601A S03 (EASI) ECG Telemetry Transmitter
Refurbished
2.00 LBS
Ships in 24 hours
Calculated at checkout
Product Description
The Philips M2601A Telemetry system transmitter sends continuous ECG and SpO2 measurements to the IntelliVue Information Center, where the measurements are captured, analyzed, displayed, and stored.
The basic setup comes with 3-lead or 5-lead capability. The ECG-only transmitter is particularly light and comfortable for patients. Upgraded transmitters combine standard and EASI derived 12-lead ECG monitoring on a single device, run on easily replaceable AA batteries, and provide audio feedback for many tasks, including “power on” and SpO2 spot check.
The basic setup comes with 3-lead or 5-lead capability. The ECG-only transmitter is particularly light and comfortable for patients. Upgraded transmitters combine standard and EASI derived 12-lead ECG monitoring on a single device, run on easily replaceable AA batteries, and provide audio feedback for many tasks, including “power on” and SpO2 spot check.
Features:
![Philips telemetry monitor manual user Philips telemetry monitor manual user](/uploads/1/1/2/2/112228183/899887857.jpg)
- Frequency of 460-480 MHz or 608-614 MHz WMTS
- Lightweight—less than ½ lb.
- Standard ECG configuration with 3- or 5-lead capability
- EASI ECG configuration used for transmitters that work with central stations that are capable of converting a 5-wire lead set signal to 12 lead analysis by having EASI version software installed at the central station.
- SpO2 configuration used for transmitters that are used with SpO2 sensors.
Philips 5 Lead Dual ECG Leadwire - Snap ($55)
Philips 5 Lead Single Pin w/Tele Shield ECG Leadwires - Grabber ($95)
Add SpO2 Probe (Only Available with S02 Model):